CAT7 S/FTP Marine Ethernet Cable
CAT7 S/FTP
4-Pair 23AWG Shipboard-Grade Copper LAN Cable — Marine & Offshore Network Focus
CAT7 S/FTP is a marine Ethernet cable built for vessel and offshore-platform data networks. Four twisted pairs of 23AWG bare copper conductors with foam-PE insulation, each pair individually screened with AL/Mylar foil, and the whole assembly finished with a tinned-copper-braid overall screen — the double-screening (S/FTP) construction required where radar, radio, navigation and power-conversion equipment share the same cableways. The SHF1 halogen-free, low-smoke outer sheath is specified against IEC 60092-360 and the cable meets the full marine fire-safety package: IEC 60332-3-22 bunched flame test, IEC 60332-1, IEC 60754-1/-2 acid-gas and conductivity limits, and IEC 61034-2 smoke density. Electrical performance follows IEC 61156-5, with conductor DC resistance ≤95 Ohm/km, characteristic impedance 100±10 Ohm @100MHz and insulation resistance ≥5000 MΩ·km. Purpose-built for wheelhouse, engine-room, accommodation and offshore control-room networks, working cooperatively with the complete KAIDUNTECH marine camera, monitor and network-hardware range to deliver a full shipboard CCTV and data-transmission backbone.
🎯 Customer Pain Points
Shipboard and offshore-platform network cabling faces these core challenges:
Mandatory shipboard cable certification
Cables installed in official marine surveillance, navigation and automation projects must satisfy shipboard cable standards — IEC 60092-360 jacket performance together with the IEC fire-safety series — to pass ship-class survey, offshore-EPC acceptance and periodic maritime safety audits. Ordinary commercial LAN cable is refused during vessel inspection regardless of its Cat rating.
Severe on-board electromagnetic interference
Ship radar, VHF/Inmarsat radio, navigation equipment and variable-frequency propulsion drives generate heavy EMI inside cableways and cabinets. Unshielded or single-screened cable suffers packet loss, link re-negotiation and video drop-outs exactly where continuous recording matters.
Fire safety and crew evacuation in enclosed spaces
Cable runs through accommodation, stairwells and machinery spaces are subject to SOLAS-related fire requirements. Halogenated (PVC) jackets release toxic hydrogen chloride and dense black smoke in a fire, endangering crew and corroding adjacent electronics. Low-smoke, halogen-free, low-acid-gas jackets are mandatory rather than optional.
Wide temperature and mechanical stress on deck and in machinery spaces
Cables run from open-deck topside areas down to engine rooms, seeing ambient extremes, vibration, repeated flexing and salt-laden air. Standard PVC jackets embrittle, crack and expose the screen; installation in cold-weather shipyard conditions also demands a defined minimum installation temperature.
Oil, fuel and UV exposure
Deck machinery, fuel-handling areas and topside masts expose cable jackets to lubricating oil, diesel and direct sunlight. A jacket without tested oil resistance (IRM 902) and UV resistance fails by swelling, hardening or surface cracking within a few seasons.
Long cable runs and PoE loading
Vessel networks involve long horizontal runs from equipment rooms to remote cameras and access points, frequently carrying PoE. High conductor resistance, poor resistance balance or low insulation resistance erodes link margin and causes camera brown-outs at the far end of the run.
Mixed equipment ecosystems and interface discipline
Bridge and control-room networks mix IP cameras, ECDIS, VDR, PA/GA, access points and third-party automation from several vendors. Stable 100 Ohm impedance, controlled capacitance unbalance and consistent screening are needed to keep every port linked without vendor-specific tuning.
CAT7 S/FTP addresses all the above pain-points: S/FTP double-screened 23AWG bare-copper construction, IEC 61156-5 transmission performance, SHF1 halogen-free low-smoke jacket to IEC 60092-360, full IEC fire-safety compliance, −52 °C to +90 °C operating range, tested oil and UV resistance. Purpose-built as the physical layer for large-scale shipboard CCTV and data networks on merchant vessels, tankers, offshore platforms and support craft.
🏭 Typical Application Scenarios
✅ Ocean-Going Merchant Vessels — Container ships, crude-oil tankers, bulk carriers: bridge, ECR, engine-room and accommodation network runs; IP camera backbone, VDR/NVR connectivity and shipboard LAN horizontal cabling.
✅ Offshore Oil & Gas Installations — FPSOs and fixed production platforms: control-room and non-hazardous-module data cabling for CCTV, PA and automation networks; low-smoke jacket suits enclosed, evacuation-critical spaces.
✅ Offshore Support Vessels & Workboats — PSVs, AHTs, crew boats: compact mast and deck-house cableways with continuous vibration, salt exposure and frequent flexing.
✅ Shipyard & Marine EPC System Integration — New-build and retrofit packages where CCTV, access control, PA and IT networks share cableways and require documented IEC test evidence for class submission.
Installation: Installed in cable trays, conduits or cabinet harnesses aboard ship and offshore units. Terminate with shielded RJ45 or industrial M12 connectors to preserve overall-screen continuity. Not armoured: where mechanical protection or direct-exposure routing is required, install inside conduit or specify an armoured variant. For Zone 1 / Zone 2 classified hazardous areas, cable routing and termination must follow the approved Ex installation drawing. Compatible with KAIDUNTECH full-series marine cameras, monitors and network hardware to build a complete end-to-end maritime transmission solution.
✨ Core Product Highlights
✅ S/FTP Double Screening for Marine EMI Environments
Individually foil-screened pairs (AL/Mylar) plus a tinned-copper-braid overall screen suppress radar, radio and drive-induced interference, protecting Gigabit link stability and video-stream continuity in shared shipboard cableways.
✅ 23AWG Bare Copper Conductors with Low Loss Budget
Bare copper, not CCA. Conductor DC resistance ≤95 Ohm/km with unbalance ≤2% within a pair and ≤5% between pairs, keeping insertion loss and PoE voltage drop under control on long vessel runs.
✅ IEC 61156-5 Transmission Performance
Characteristic impedance 100±10 Ohm @100MHz, insulation resistance ≥5000 MΩ·km, capacitance unbalance ≤160 pF/100m @1kHz, dielectric strength DC 1kV for 1 minute — a stable, standards-traceable electrical baseline for multi-vendor equipment.
✅ SHF1 Halogen-Free Low-Smoke Sheath to IEC 60092-360
Jacket material performance specified against the shipboard cable standard. Acid gas release ≤5 mg/g (IEC 60754-1), burning-gas pH ≥4.3 and conductivity <10 µS/mm (IEC 60754-2), smoke density ≥60% (IEC 61034-2).
✅ Full Marine Flame-Retardant Package
Passes IEC 60332-3-22 bunched-cable vertical flame propagation and IEC 60332-1 single-insulated-wire flame tests — the combination class surveyors expect in accommodation and machinery-space runs.
✅ −52 °C to +90 °C Operating Range with Defined Installation Window
Continuous service from −52 °C to +90 °C, with installation permitted down to −20 °C (max +60 °C), covering cold-climate new-builds, refrigerated spaces and machinery-adjacent routing.
✅ Tested Oil and UV Resistance
SHF1 sheath resistance to IRM 902 reference oil at 70 °C for 4 hours, plus UL 1581 UV exposure for 300 hours — suitable for deck machinery areas and topside runs without premature jacket ageing.
✅ Practical Marine Construction Details
Foam-PE insulation in the standard white/blue, white/orange, white/green, white/brown pair colour code for fast, error-free termination; grey sheath as standard, other colours on request; 4-pair construction sized for standard marine cabinets and cable trays.
📋 Key Specification
|
Item
|
Parameter
|
|
Type
|
CAT7 S/FTP
|
|
Conductor
|
Bare copper wire (23AWG/1)
|
|
Insulation
|
Foam PE; colour: white, blue, orange, green, brown
|
|
Individual screen
|
AL/Mylar
|
|
Insulation colour code
|
White/Blue + Blue, White/Orange + Orange, White/Green + Green, White/Brown + Brown
|
|
Overall screen
|
Tinned copper braid
|
|
Outer sheath
|
SHF1
|
|
Outer sheath colour
|
Grey or per request
|
|
Conductor DC resistance
|
≤95 Ohm/km
|
|
DC resistance unbalance
|
≤2% (within a pair), ≤5% (between pairs)
|
|
Characteristic impedance
|
100±10 Ohm @100MHz
|
|
Dielectric strength
|
DC 1kV for 1 min (conductor to conductor, conductor to screen)
|
|
Insulation resistance
|
≥5000 MΩ·km (IEC 61156-5)
|
|
Capacitance unbalance (pair to ground)
|
≤160 pF/100m at 1kHz (IEC 61156-5)
|
|
Transmission performance
|
IEC 61156-5
|
|
Operating / installation temperature
|
−52 °C to +90 °C / −20 °C to +60 °C
|
|
Acid gas release
|
≤5 mg/g (IEC 60754-1)
|
|
Burning-gas acidity / conductivity
|
pH ≥4.3 (IEC 60754-2) / <10 µS/mm (IEC 60754-2)
|
|
Smoke density
|
≥60% (IEC 61034-2)
|
|
Flame resistance
|
IEC 60332-3-22, IEC 60332-1
|
|
Oil resistance (SHF1)
|
IRM 902, 70 °C × 4 h
|
|
UV resistance
|
UL 1581 (300 h)
|
|
Jacket material performance
|
IEC 60092-360
|
|
Application note
|
Non-armoured construction; use conduit or armoured variant where mechanical protection is required
|
|
Matching devices
|
KAIDUNTECH marine IP cameras, marine monitors, industrial switches and NVRs
|
📦 Lead-Time & Warranty Terms
|
Item
|
Details
|
|
Standard construction
|
3–4-week production lead-time upon deposit receipt
|
|
Custom version
|
5–6-week lead-time for sheath colour, length, printing or screening adjustments
|
|
Deliverables
|
Datasheet, reel-length confirmation, IEC 61156-5 / fire-test batch reports, packing list
|
|
Warranty
|
12-month standard material warranty; extended-warranty duration negotiable via separate commercial quotation
|
|
Non-conformance handling
|
Defective cable or drum damage supported by factory-return replacement service
|
|
Value-added support
|
Termination guidance, screen-continuity and link-test recommendations, marine-project documentation support
|
|
Packaging & logistics
|
Wooden drum / export carton; lengths per project schedule; EXW, FOB and other international-trade terms; consolidated shipment with marine cameras and monitors
|
⚠️ Reminder: CAT7 S/FTP is a non-armoured, halogen-free shipboard LAN cable for tray, conduit and cabinet installation. It is not a substitute for certified armoured or Ex-approved cable where mechanical protection, direct-exposure routing or hazardous-area installation is required. Minimum installation temperature is −20 °C; avoid bending below this limit. Terminations must maintain overall-screen continuity to preserve EMI performance. Off-the-shelf stock cannot be guaranteed — place orders ahead of ship-building and vessel-retrofit milestones. Installation must comply with IEC marine-system safety regulations and the approved project cable schedule.
📝 Reference Success Stories
Case 1 | New-Build Container-Ship CCTV & LAN Backbone
- Project challenges: A new-build large container ship required a halogen-free, low-smoke shielded cable for bridge, ECR and deck camera networks, with documented IEC 61156-5 and fire-test evidence for class survey, EMI immunity inside shared cableways, and PoE-capable runs to remote deck cameras.
- Solution: CAT7 S/FTP supplied in project lengths for tray installation, terminated with shielded connectors; screen continuity verified end-to-end; batch test reports submitted with the cable schedule.
- Outcome: Cable package accepted at class survey; deck and cargo-area camera links ran stable under radar and VHF operation; no link re-negotiation reported during commissioning.
Case 2 | FPSO Control-Room Network Retrofit
- Project challenges: An FPSO retrofit needed to renew control-room and module data cabling for CCTV, PA and automation, within existing trays and with low-smoke material requirements for enclosed spaces, plus an operating range covering hot machinery-adjacent routing.
- Solution: CAT7 S/FTP installed in existing trays with shielded terminations, colour code matched to the existing schedule for minimal re-termination errors; oil- and UV-resistant sheath specified for the exposed module runs.
- Outcome: Retrofit network passed offshore site safety acceptance; stable camera and PA links across all modules; jacket unaffected in oil-exposed deck machinery areas after the first service cycle.
❓ FAQ
Q1: What standards does this cable meet?
A: Transmission performance to IEC 61156-5; jacket material performance to IEC 60092-360; flame resistance to IEC 60332-3-22 and IEC 60332-1; acid gas to IEC 60754-1/-2; smoke density to IEC 61034-2; oil resistance to IRM 902; UV resistance to UL 1581.
Q2: Why S/FTP rather than F/UTP or U/UTP?
A: S/FTP screens each pair individually with foil and the whole cable with a tinned-copper braid. The braid adds low-frequency and mechanical-noise immunity that foil-only designs lack, which is what shipboard radar, radio and drive interference demands.
Q3: Does it support PoE cameras?
A: Yes. 23AWG bare copper with ≤95 Ohm/km conductor resistance and tight resistance balance keeps voltage drop and heat rise low over long runs. Confirm total run length and PoE class against the camera datasheet.
Q4: Is it suitable for open-deck installation?
A: The sheath is tested for oil (IRM 902) and UV (UL 1581, 300 h), so exposed topside routing is acceptable where the cable is mechanically protected in a tray or conduit. The construction is non-armoured — use an armoured variant where direct mechanical impact is possible.
Q5: What is the operating temperature range?
A: −52 °C to +90 °C in service; installation is permitted from −20 °C to +60 °C. Do not bend at temperatures below −20 °C.
Q6: Can it be installed in Zone 1 / Zone 2 hazardous areas?
A: Cable routing and termination in classified areas must follow the approved Ex installation drawing for the unit. This cable is not itself an Ex-certified component; hazardous-area installation is a system-level approval matter.
Q7: What termination is recommended?
A: Shielded RJ45 in cabinets, or industrial M12 X-code on deck. The overall braid screen must be bonded at the connector shell to keep screening effectiveness; unterminated screens convert the cable into an antenna.
Q8: Which pair colour code is used?
A: White/Blue + Blue, White/Orange + Orange, White/Green + Green, White/Brown + Brown — the standard code for fast, consistent termination. Other colour sequences available on request.
Q9: Are test reports and custom lengths available?
A: Yes. Batch test reports for IEC 61156-5 electrical performance and the fire-test series are available for class submission; sheath colour, printing and reel length can be customised with a 5–6-week lead-time.