KD‑XL‑8X
4×2×0.5 Marine Watertight Cable
Industrial‑grade marine watertight shielded cable KD‑XL‑8X, constructed with tinned‑copper conductors, PE insulation, aluminium‑foil shielding and durable polyether‑polyurethane outer jacket. Rated voltage 300/500 V, operating temperature range ‑40 ℃ ~ +80 ℃. Designed for fixed and mobile onboard / offshore equipment wiring, delivering reliable signal transmission, excellent water‑resistance, anti‑interference and mechanical toughness. Ideal matching cable for marine cameras, explosion‑proof surveillance equipment and various marine‑system field installations.
🎯 Customer Pain Points (Maritime‑Focused)
Marine and offshore system wiring projects frequently face these real‑world practical challenges:
- Moisture and seawater intrusion risk On‑board and offshore wiring routes are exposed to humidity, sea‑spray and occasional water splashing. Ordinary common cables suffer water ingress leading to insulation degradation, signal short‑circuit and premature cable failure.
- Electromagnetic interference on vessel platforms Ship power equipment, motors and high‑power onboard devices generate heavy electromagnetic noise. Un‑shielded cables result in distorted video / control signals, causing picture noise and abnormal device communication.
- Demanding wide‑temperature working conditions Vessels and offshore facilities operate across frigid polar waters to hot tropical zones. Cables must maintain stable performance under large temperature fluctuations.
- Mechanical stress during installation & operation Cables face bending, pulling, friction for both fixed laying and dynamic mobile equipment connection. Poor jacket material causes cracking and damage under repeated mechanical stress.
- Corrosion risk in marine environment Ordinary bare‑copper conductors are prone to oxidation and electrochemical corrosion under salt‑fog atmosphere, raising connection resistance and causing intermittent signal faults.
- Matching requirement for marine surveillance systems Marine cameras, explosion‑proof monitors and auxiliary devices require dedicated watertight marine‑rated cables. Using general‑purpose land cables risks project acceptance failure during ship‑survey and offshore safety inspection.
- Project‑schedule risk for specialised marine‑grade cabling supplies Qualified marine watertight cables are supporting niche‑accessories for maritime security projects. Ambiguous lead‑times may delay new‑build and vessel‑refit construction milestones.
KD‑XL‑8X addresses all above‑mentioned maritime pain‑points: 4×2×0.5 watertight shielded marine cable with tinned‑copper conductors, aluminium‑foil shielding and polyether‑polyurethane outer sheath. Purpose‑built for fixed and mobile wiring of marine surveillance and automation equipment aboard ships and offshore installations.
🏭 Typical Application Scenarios
✅ Merchant Cargo Vessels: Bulk carriers, container ships, multi‑purpose vessels | Signal wiring for marine cameras, sensors and auxiliary surveillance equipment; fixed laying and partial mobile cable runs ✅ Special‑Purpose Work Vessels: Offshore supply vessels, engineering vessels, patrol crafts | Deck‑area equipment interconnection, bridge‑system signal transmission ✅ Off‑shore Facilities: Coastal offshore auxiliary modules | Non‑hazard signal wiring for offshore monitoring devices (match with explosion‑proof accessories for hazardous‑zone deployment) ✅ Coastal On‑shore Sites: Port and harbour facilities exposed to salt‑fog atmosphere | Industrial salt‑resistant signal‑cable deployment
Installation: Suitable for fixed laying and limited‑movement mobile installation. Recommend to pair with KAIDUNTECH marine flexible hoses, anti‑corrosion junction boxes and cable glands to realise complete marine‑grade wiring solution.
✨ Core Product Highlights
✅ Tinned‑Copper Conductor for Anti‑Corrosion Performance Adopts multi‑strand tinned‑copper conductor (28/0.15 mm strand, strand outer‑diameter 0.9 mm). Tin‑plating effectively resists salt‑fog oxidation and electrochemical corrosion in marine atmosphere, stabilising electrical‑contact performance and extending service life.
✅ PE Insulation with Clear Colour‑Coding High‑quality PE insulation, insulation thickness 0.35 mm, finished insulation outer‑diameter 1.60 mm. Four‑core colour identification: Red / Black / Yellow / Blue, facilitating on‑site wiring, identification and maintenance work.
✅ Aluminium‑Foil Shielding for Anti‑EMI Interference Complete aluminium‑foil wrapping shielding structure. Effectively suppresses electromagnetic interference generated by ship‑board motors, power‑distribution equipment, guaranteeing clean and stable transmission of video, control and data signals.
✅ Robust Polyether‑Polyurethane Outer Jacket Polyether‑polyurethane jacket material, jacket thickness 1.4 mm, finished cable approximate outer‑diameter 9.0 mm. Black outer sheath delivers outstanding water‑resistance, low‑temperature flexibility, abrasion‑resistance and anti‑aging properties, adapting to complex marine laying environments.
✅ Reliable Electrical & Wide‑Temperature Performance Rated voltage:300/500 V. Broad operating temperature range ‑40 ℃ ~ +80 ℃. Supports both fixed installation and appropriately‑restricted mobile use scenarios.
✅ Optimised Matching for KAIDUNTECH Marine Equipment Portfolio Specially‑adapted for signal connection of marine bullet / dome cameras, crane damping cameras and other marine‑surveillance devices. Convenient for unified project material procurement and system integration for new‑build and refit ship projects.
📋 Key Specification
表格
| Item |
Parameter |
| Model |
KD‑XL‑8X |
| Cable Type |
4×2×0.5 Watertight shielded marine cable |
| Conductor |
Tinned copper wire; 28/0.15 mm strands; strand OD:0.9 mm |
| Insulation Material |
PE |
| Insulation Thickness |
0.35 mm; Insulation OD:1.60 mm |
| Insulation Colour Code |
Red, Black, Yellow, Blue |
| Shielding |
Aluminium foil wrapping |
| Outer Jacket Material |
Polyether polyurethane |
| Jacket Thickness |
1.4 mm |
| Jacket Colour |
Black |
| Approx. Overall Outer Diameter |
9.0 mm |
| Rated Voltage |
300/500 V |
| Operating Temperature |
‑40 ℃ ~ +80 ℃ |
| Application Mode |
Fixed installation / suitable for limited‑range mobile laying |
📦 Lead‑Time & Warranty Terms
| Item |
Details |
| Standard Model |
3‑4‑week production lead‑time upon deposit receipt |
| Custom‑modified Version |
5‑6‑week lead‑time for custom conductor cross‑section, core‑count, sheath‑material and special marking requirements |
Deliverables: Cable technical datasheet, test report excerpts, packing list for new‑build / refit project review documentation submission.
Warranty Terms ‑ 12‑month standard warranty under correct installation and application conditions. ‑ Value‑added support: technical guidance for marine‑cable laying, supporting documentation for ship‑project bidding and review.
Packaging & Logistics: Export‑grade reel‑packaging. Supports EXW, FOB and other international trade terms. Consolidated shipment with marine cameras, hoses and junction‑box orders.
⚠️ Reminder: KD‑XL‑8X is specialised marine watertight signal cable. Please confirm required total length when placing orders. For hazardous explosive zones, must cooperate with certified explosion‑proof cable‑glands and junction boxes.
📝 Reference Success Stories
Case 1 | New‑Build Offshore Supply Vessel Surveillance‑System Wiring Project
‑Project Challenges: New‑build offshore supply vessel requires large‑quantity marine‑grade signal cables for multi‑point marine‑camera deployment. Deck environment features salt‑fog, wide temperature swings and electromagnetic interference from onboard power machinery; cable shall be applicable for both fixed laying and partial mobile sections; material documents are required for ship‑survey review. ‑Solution: Adopt KD‑XL‑8X 4×2×0.5 watertight shielded marine cable. Match with marine flexible hoses and anti‑corrosion junction boxes for complete protected wiring construction. ‑Outcome: Tinned‑copper conductor and shielding structure resist marine corrosion and electromagnetic interference. Cable maintains stable performance under full‑range ship‑board temperature conditions. Wiring material documentation meets ship‑survey submission requirements. Project passed vessel‑equipment acceptance.
Case 2 | Coastal Cargo‑Ship Surveillance‑Refit Wiring Upgrade Project
‑Project Challenges: In‑service coastal cargo‑ship refit‑project. Replace aged ordinary land‑spec cables. Require watertight anti‑interference signal cable to connect upgraded marine cameras, compatible with existing on‑board surveillance system for periodic equipment inspection. ‑Solution: Deploy KD‑XL‑8X marine watertight cables for camera signal loops, follow marine‑standard laying specifications. ‑Outcome: Effectively eliminates signal noise caused by onboard electromagnetic interference. Cable resists salt‑fog and humidity. Stable signal transmission fulfils refit‑project acceptance requirements.
❓ FAQ
Q1: What are the main applications of KD‑XL‑8X watertight cable? A: KD‑XL‑8X is a 4×2×0.5 shielded watertight marine‑grade signal cable, mainly used for signal interconnection of marine cameras, sensors and surveillance auxiliary equipment. It supports fixed laying and limited‑range mobile installation on ships and offshore platforms.
Q2: Why use tinned‑copper conductors for marine‑grade cables? A: Tinned‑copper conductors add tin‑plating layer to copper strands, effectively inhibiting oxidation and salt‑fog electrochemical corrosion in maritime salt‑humid environment, preventing bad‑contact and intermittent signal faults.
Q3: What is the function of aluminium‑foil shielding? A: Aluminium‑foil wrapping shielding suppresses electromagnetic interference from ship‑board motors and power‑distribution equipment, avoiding video‑noise and communication anomalies to guarantee stable signal transmission.
Q4: Can this cable be used in explosive hazardous zones? A: The cable itself is marine watertight signal‑cable. When deployed in explosion‑classified hazardous locations, it must be used together with ATEX‑certified explosion‑proof cable‑glands and junction‑boxes, complying with local hazardous‑area installation‑codes.
Q5: What are temperature and voltage ratings? A: Rated voltage 300/500 V, operating temperature range:‑40 ℃ ~ +80 ℃, adapting to global marine climate conditions.
Q6: Is customisation available? A: Yes, customisable conductor cross‑section, core‑number, sheath‑material and cable marking. Custom lead‑time 5‑6 weeks upon requirement confirmation.
Q7: What accessories are recommended for installation? A: Recommended matching accessories: KDR‑1500 Rubber Flexible Hose, KDSR‑1500 Stainless Steel Flexible Hose, KDJ004 Anti‑Corrosion Junction Box, KDP001 Stainless‑Steel Joint Connector, explosion‑proof cable‑glands (for hazardous‑zone use).